AKG-Line AR (Dusty environment)

FEATURES OF THE AKG-Line AR

  • The coolers are equipped with anti-clogging fins
  • 400 volt motor powered fan.
  • Can be exposed to operating pressures of up to 26 bar or 17 bar, depending on model
  • High-Performance cooling assemblies
  • The heat is transferred from the medium to be cooled to the ambient air
  • Cooler can be universally used in hydraulic oil, transmission oil, engine oil, lubricating oil and coolant circuits
  • For the cooling of mineral oil, synthetic oil, biological oil as well as of HFA, HFB, HFC and HFD liquids and water with at least 50 per cent of antifreeze and anticorrosive additives [other media available]
  • Noise-optimized models available [low-noise series]

PDF datasheet
Datasheet AKG-Line AR Oil cooler (dusty environment) 400 Volt fan

Technical Data AR105B oil cooler with anti-clogging fin system AKG

Volume 15 liter
Maximum working pressure 26 bar (g)
Weight 100 kg
Voltage 400 Volt / 50 Hz
Motor power 2.2 Kw
Engine speed 1500 rpm / 4 pole
Fan ø 660 mm
Airflow Blowing
Noise level 80 dB
Heat rejection < 105 kW

technical drawing AR105B oil cooler with anti-clogging fin system AKG

Product codes AR105B oil cooler with anti-clogging fin system AKG

  CCS no. AKG nr. (Old) AKG nr. (New)
AR105B Complete 2010.200.1100 1963.044.X084 0
 
Cooler 6010.200.0100 1963.032.1X84 1100652200
Motor bracket 1400157400
Foot 7810.030.0000 1963.007.7200 1400157600
Shroud 7410.060.0000 1963.008.4010 1500156300
Motor 7010.090.4000 8407.173.4422 1500453000
Fingerguard 7610.090.0000 8402.079.0000 1500489900
Fan 7250.066.0201 8400.375.0660 1500554000

Description Value
COOLER_TYPE Default
Volume 15
Maximum working pressure 26
Weight 100
Voltage 400
Frequency 50
Motor power 2.2
Engine speed 1500
poles 4
Low noise NO
Fan ø 660
Airflow Blazend
Noise level 80
Heat rejection 50
Environment Contaminated
Connection Default
Nominal speed 1500
Motor size 90