AKG-Line AP (+hydropump)

FEATURES OF THE AKG-Line AP

  • 400 volt motor powered fan and hydro pump.
  • The heat is transferred from the medium to be cooled to the ambient air.
  • Cooler can be universally used in hydraulic oil, transmission oil, engine oil and lubricating oil
  • For the cooling of HLP mineral oil to DIN 51524 and 100 cSt [other media and viscosity available at request]
  • Ambient temperature from -20 C up to +80 C
  • Max. oil temperature 80 C
  • Pump rated suction pressure 0,7 – 2 bar [0,5 bar when starting]
  • Largest and most comprehensive series of industrial coolers.
  • Filter optional = 20m filter unit
  • Filter bypass 2 bar.

PDF datasheet

Technical Data AP12-20 oil cooler with pump 20cm³ AKG

Oilflow (optimal) 30 L/min
Volume 4.9 liter
Weight 54 kg
Voltage 400 Volt / 50 Hz
Motor power 2.2 Kw
Engine speed 1500 rpm / 4 pole
Fan ø 290 mm
Airflow Sucking
Noise level 60 dB
Heat rejection < 6.7 kW

technical drawing AP12-20 oil cooler with pump 20cm³ AKG

Product codes AP12-20 oil cooler with pump 20cm³ AKG

  CCS no. AKG nr. (Old) AKG nr. (New)
AP12-20 Complete 2015.040.0000 1963.901.X084 1100882000
 
Cooler 6010.040.0000 1963.001.1X84 1100649700
Motor bracket 1400157400
Shroud 7410.010.0000 1963.001.4010 1500155800
Fingerguard 7610.010.0000 8402.111.0000 1500418300
Foot left 7810.210.1000 1963.301.7200
7810.210.2000 1963.301.7300
Motor 7010.100.4050 8407.170.7822
Pump 7110.020.0000 8407.470.0303
Hydraulic hose 7190.500.0000 8062.066.0000
7190.601.0000 8425.401.1019
Fan 7250.029.0004 8400.337.0290
Pump carrier 8050.010.0000 8408.003.0002

Description Value
COOLER_TYPE Pomp
Volume 4.9
Weight 54
Voltage 400
Frequency 50
Motor power 2.2
Engine speed 1500
poles 4
Low noise NO
Fan ø 290
Airflow Zuigend
Noise level 60
Heat rejection 70
Environment Default
Oilflow (optimal) 30
Connection Default
Manufacturer AKG
Nominal speed 1500
Motor size 100